Table 1 Patient demographic data

From: Intramedullary rod insertion places the femoral component more laterally during Oxford medial unicompartmental knee arthroplasty

Knees/patients

53/45

Sex, female/male

32/13

Diagnosis, OA/SONK

46/7

Age, years

73.8 ± 7.4

BMI, kg/m2

25.1 ± 4.1

Preoperative FTA

182.1 ± 3.7

ROM

134.8 ± 15.6

OKS

25.5 ± 7.5

KSS functional

55.6 ± 25.8

  1. Unless otherwise specified, data are given as mean ± standard deviation. BMI body mass index, OA osteoarthritis, SONK spontaneous osteonecrosis of the knee, FTA femorotibial angle, ROM range of motion, OKS Oxford Knee Score, KSS Knee Scoring System