Skip to main content

Table 3 Comparison of incidence and depth of notching between FBRD and FBRE groups, in overall patients and in subset of patients with PFC-Sigma and Attune implants

From: Notching is less, if femoral component sagittal positioning is planned perpendicular to distal femur anterior cortex axis, in navigated TKA

Parameters

FBRD group

FBRE group

p-Value

Overall patients

n = 171

n = 171

 

Incidence of notching

34/171 (19.9%)

12/171 (7%)

0.0007

Mean notch depth (mm)

1.53 ± 0.71

(R = 0.2–3.3)

0.98 ± 0.53

(R = 0.3–2.2)

0.009

Patients with PFC-Sigma implant

n = 93

n = 93

 

Incidence of notching

24/93 (25.8%)

10/93 (10.8%)

0.0128

Mean notch depth (mm)

1.58 ± 0.76

(R = 0.2–3.3)

1.07 ± 0.53

(R = 0.6–2.2)

0.035

Patients with Attune implant

n = 78

n = 78

 

Incidence of notching

10/78 (12.8%)

2/78 (2.6%)

0.0315

Mean notch depth (mm)

1.41 ± 0.58

(R = 0.5–2.2)

0.55 ± 0.35

(R = 0.3–0.8)

0.0934

  1. FBRD femur anterior bowing registration disabled; FBRE femur anterior bowing registration enabled; mm millimetre; n number of knees; R range